Scintacor offers both Gadox and BFC based x-ray screens.
Luminex – Terbium-doped gadolinium oxysulphide (Gadox:Tb). This phosphor is also known as P43.
Rapidex – Praseodymium-doped gadolinium oxysulphide (Gadox:Pr) for hard X-ray applications (50-300 keV).
MeVex – A very high coating weight screen made of terbium-doped gadolinium oxysulphide (Gadox:Tb) for use at high-energy energy levels (>450 keV – 25 MeV).
BFC – A fast-responding Europium-doped BaFCl phosphor for backscatter x-ray imaging applications.
The properties of these screens are listed in Table 1.Scintacor offers both Gadox and BFC based x-ray screens.
Light Output (1) | MTF % @ 2lp/mm (2) | MTF % @ 5lp/mm (2) | Attenuation % (2) | Decay to 10% μs | Afterglow @ 20ms % | |
Ultrabright | 205% | 18 | 4 | 92 | 1,500 | <0.1% |
Bright | 175% | 21 | 7 | 92 | 1,500 | <0.1% |
Medium | 170% | 23 | 5 | 91 | 1,500 | <0.1% |
Fine | 129% | 42 | 15 | 86 | 1,500 | <0.1% |
UltraFine | 70% | 65 | 29 | 83 | 1,500 | <0.1% |
UltraFine Plus | 50% | 76 | 45 | 76 | 1,500 | <0.1% |
Hyperfine | 36% | 85 | 67 | – | 1,500 | <0.1% |
| Light Output (1) | MTF % @ 2lp/mm (2) | MTF % @ 5lp/mm (2) | Attenuation % (2) | Decay to 10% μs | Afterglow @ 20ms % |
Bright | 92% | 16 | 4 | 97 | 7 | <0.1% |
Medium | 91% | 19 | 5 | 94 | 7 | <0.1% |
Fine | 81% | 32 | 9 | 89 | 7 | <0.1% |
MeVex | Light Output (1) | MTF % @ 1lp/mm (2) | MTF % @ 2lp/mm (2) | Attenuation % (2) | Decay to 10% μs | Afterglow @ 20ms % |
Medium | 242% | 16 | <10 | 98 | 1,500 | <0.1% |
Emission peak | 390nm 70kV, 140μA x-ray |
Decay | 6.4 μs Cs-137 8.542Ci source 3000 pulses |
Afterglow | 0.2% After 20mS |
Light Output | 26% Ref. Lanex Regular 70kV, 140μA x-ray |
(1) Relative to Lanex Regular benchmark screen. X-ray source: 150kV unfiltered
(2) X-ray source 70kV
Size & geometry.
Unlike other commercially available products, Scintacor X-ray screens can be ordered in single units and custom-cut to any shape and size, to match the specific requirements of each application.
Large sheets are available with linear dimensions up to 1,000×1,750mm. On request, the screens can also be supplied in precision-cut strips as thin as 3-4mm for coupling to linear diode arrays. They can be mounted on a variety of substrates for easier handling and deployment.
The Luminex screens can be used as replacement for X-ray scintillator screens by other manufacturers. Table 2 below provides the approximate equivalence among Scintacor designations and those of other manufacturers. This table does not imply the exact equivalence of the various screens and we invite you to contact Scintacor personnel for further guidance.
Scintacor | Mitsubishi | Carestream | Agfa |
Ultrabright | P1200 | – | – |
Bright | DRZ-High | Lanex Fast | Ortho Fast |
Medium | DRZ-Plus | Lanex ragular | Ortho Regular |
Fine | DRZ-Std | Lanex Medium | Ortho Medium |
UltraFine | DRZ-Fine | Lanex Fine | Ortho Fine |
UltraFine Plus | DRZ-HR | Lanex Min-R | – |
HyperFine | – | – | – |
(*) Disclaimer. Headings and keywords in the table above are descriptive of the products offered by Scintacor to show which of Scintacor’s products is best suited as replacement of a similar product made by another company. The trademarks P100/DRZ, Lanex/MinR and Ortho are the property of Mitsubishi Chemical Corporation, Carestream Health and Agfa HealthCare respectively.
Levy and West, the founders of the renowned laboratories which later became Applied Scintillation Technologies and then Scintacor, were among the pioneers who explored the use of zinc sulphide phosphors for fluoroscopic X-ray imaging. Since then, many additional phosphor systems have been developed and today we find gadolinium oxysulphide (Gd2O2S or simply Gadox / GOS) phosphor is one of the most widely adopted for several reasons. The material morphology is well known and well controlled; the luminescent efficiency is relatively high (approximately 15%) and the emitted light matches well with the spectral response of silicon light detection devices such as charge-coupled detectors (CCD) and complementary metal oxide semiconductors (CMOS).
Gadox scintillator screens were originally developed and commercialized by companies which supplied photographic film and were often described as ‘fine’, ‘regular’ or ‘fast’ depending upon the film speed and spatial resolution of the film with which they were paired. These screens are still widely available up to a maximum size of 14’’x 17’’ but they do not always provide the optimal solution for digital X-ray imaging. Conversely, Scintacor phosphor screens have been specifically designed around digital X-ray imaging systems to provide differentiated performance over standard scintillator screens, in both lens-coupled systems, and direct-coupling to solid-state light detectors, such as CMOS and CCD.
+44 (0)1223 223 060
info@scintacor.com
Contact Form
125 Cowley Road
Cambridge Commercial Park
Cambridge, CB4 0DL
United Kingdom